Our Approach and Scope
Our process entails a comprehensive assessment of compressor operations, encompassing a detailed evaluation of load conditions, operating pressures, and sizing criteria. Additionally, we investigate opportunities for waste heat recovery and pinpoint any existing leaks. Using ultrasonic leak detector, we conduct a rigorous air leak audit, labelling all leaks exceeding 2 liters per minute (LPM). Any critical leaks, those exceeding 24 LPM, are marked with a red tag, and immediate communication is made with on-site personnel to address and prioritize their resolution.